ILX LIGHTWAVE LDX-36040-30 CALIBRATION and ILX LIGHTWAVE LDX-36040-30 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the ILX LIGHTWAVE LDX-36040-30 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Diode Controller?
Shop for Comparable Products on our
 used Laser Diode Controller page

 
   ILX LIGHTWAVE LDX-36040-30   Description / Specification:    
ILX LIGHTWAVE LDX-36040-30 40A/80A, 30V Laser Diode Current Source

The ILX Lightwave LDX-36040-30 High Power Laser Diode Driver is a 40A and 30V current source that offers CW, QCW, and Hard Pulse Output with multiple levels of laser diode protection. The LDX-36040-30 can be operated at full scale current and voltage in CW or QCW mode saving time and reducing cost of test by eliminating multiple instruments and test set-ups. Conduct CW L-I-V testing and pulse testing of high power laser diodes all at the same test station, without moving the laser or changing the output cable. With the 36000’s there is no need for another QCW instrument, simply change operating modes from the front panel or through the GPIB interface, set up the test parameters and start testing quickly in either mode. In QCW mode, the pulse output can be generated either internally with programmable pulse width, duty cycle and frequency parameters or through an external pulse trigger, output up to 80A at 30V. In addition the LDX-36040-30 features 4-wire voltage measurement, photodiode measurement, and a trigger in and out. For automated testing applications in an R&D or production environment, remote operation is easily accomplished through the GPIB/IEEE-488 interface. Specifications. Output Current Range: 0 to 40 A. Output Current Accuracy: ±(0.1% of FS +20 mA). Laser Output Compliance Voltage: 0 to 30 V. Current Output Short-Term Stability (1 h): <100 ppm FS. Photodiode Reverse Bias: 0 to 15 V. Monitor Current Accuracy: +0.1% of FS. Forward Voltage Resolution: 10 mV. Forward Voltage Accuracy: +0.05% of 20mV. Laser Output Noise/Ripple (rms) Hi BW: <10 mA. Temperature Coefficient: <50 ppm FS/°C. Display Type: 5-digit Green LED. Computer Interface: GPIB.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the ILX LIGHTWAVE LDX-36040-30. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chromatic Dispersion
Chromatic Dispersion is a broadening of the input signal as it travels down the length of the fiber. Chromatic Dispersion results from a variation in propagation delay with wavelength, and is affected by fiber materials and dimensions.

Detector
A Detector is a signal conversion device that converts power from one form to another, such as from optical power to electrical power

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Polarization Mode Dispersion (PMD)
Polarization mode dispersion (PMD) is a form of modal dispersion where two different polarizations of light in a waveguide, which normally travel at the same speed, travel at different speeds due to random imperfections and asymmetries, causing random spreading of optical pulses. It is he difference between the maximum and minimum values of loss typically measured in ps/km^1/2.


Please contact us for your ILX LIGHTWAVE LDX-36040-30 CALIBRATION and/or ILX LIGHTWAVE LDX-36040-30 40A/80A, 30V Laser Diode Current Source REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: